INFINITE UPSIDE

Electric cars and charging

How long does EV charging take as power changes?

A charger’s maximum power is not necessarily the average power delivered through the session.

To estimate an electric vehicle's charging time, first identify how much energy the battery needs between its starting and target charge levels. Then use a realistic average charging power for that interval—not just the highest number advertised on the charger. Charging power can change during a session, so a peak-power division is an optimistic calculation unless the vehicle actually sustains that power for the entire energy amount.

Keep charging time separate from the time spent reaching a station, waiting for a compatible charger, starting a session and getting back on the road. The result is a planning estimate, not a promise that a charger will be available or that the car will accept a particular rate. The calculations below use fictional inputs; follow the vehicle and charging-equipment instructions for the actual equipment.

Separate power from energy

A kilowatt (kW) is a rate of power. A kilowatt-hour (kWh) is an amount of energy. If a battery actually receives a constant 10 kW for one hour, it receives 10 kWh during that hour. At a constant 10 kW for half an hour, it receives 5 kWh.

For a period with a known constant or interval-average battery-side power, the relationship is energy in kWh = average power in kW × time in hours. Rearranged, time in hours is energy divided by average power. Multiply hours by 60 to express the result in minutes.

The word average matters. If power rises or falls during the period, one moment's reading does not describe the whole interval. And a charger's maximum rating is not necessarily the power the vehicle receives at every moment. It is a capability limit or rating, not an observed session average.

This guide's worked powers are expressly measured at the battery-energy side of the example. A station's meter or electrical supply may measure a different boundary. Charging losses and other loads can make energy taken from the grid differ from energy added to the battery. Do not divide a battery-side energy target by a grid-side power figure without a justified conversion.

Set a specific start and target

Imagine an electric vehicle with a supplied usable battery-energy range of 80 kWh. In this fictional example only, assume the displayed charge percentage moves linearly across that usable range: 20% corresponds to 16 kWh in this defined range, and 80% corresponds to 64 kWh. The owner wants to go from 20% to 80%.

The change is 60 percentage points, not 80 percentage points. Under the supplied linear assumption, energy added to the battery is 80 kWh × (0.80 − 0.20) = 48 kWh. The initial 16 kWh remains part of the starting state; it is not energy newly delivered during the session.

Usable energy, displayed percentages and their relationship are vehicle-specific. A published total pack capacity, a dashboard percentage and usable energy available between two points may not have the same definition. If the usable range or mapping is unknown, the 48 kWh result is not established. Use vehicle-specific information or a measured session record rather than assuming every percentage point represents the same amount of usable energy.

The National Renewable Energy Laboratory charging-network report describes how actual DC charging times vary with starting and ending charge, battery temperature, vehicle management and station capabilities. Its fleet analysis uses its own modeling assumptions; it does not supply this guide's 80 kWh battery or the fictional rates below.

See why a peak rate is not the answer

Suppose a compatible DC station is rated up to 150 kW. Dividing the 48 kWh battery-energy target by 150 kW gives 0.32 hours, or 19.2 minutes. That is a useful idealized arithmetic benchmark only if 150 kW reaches the battery continuously throughout the interval.

Even if the assembly could accept 150 kW briefly, that does not establish a 150 kW average. The car or station may limit power, the battery may be outside its preferred temperature range, and power can decline as the battery fills. A station rating alone cannot determine the actual charge curve or guarantee completion in 19.2 minutes.

Suppose the vehicle reaches a 120 kW battery-side rate during the session. Dividing 48 kWh by 120 kW gives 0.4 hours, or 24 minutes. This second benchmark is also conditional: it assumes that rate is sustained on average over the entire energy addition. A single observed peak does not establish that assumption.

Both divisions are arithmetically correct. Their weakness is the assumed power. They describe different imaginary sessions, not two measured completion times for the same vehicle.

Calculate a supplied two-interval session

For a more informative fictional schedule, keep the 80 kWh usable range and the 20% to 80% target. Suppose battery-side power averages 120 kW from 20% to 50%, then 60 kW from 50% to 80%. Each average includes all variation within its own interval; it is supplied as an input, not deduced from a momentary screen reading.

The first interval spans 30 percentage points, so the battery receives 80 × 0.30 = 24 kWh. At an average of 120 kW, time is 24 ÷ 120 = 0.2 hours, or 12 minutes.

The second interval also adds 24 kWh. At an average of 60 kW, time is 24 ÷ 60 = 0.4 hours, or 24 minutes. Total battery energy is 48 kWh and total charging time is 12 + 24 = 36 minutes.

Scroll horizontally to see all columns.

Fictional battery-side charging schedule
Charge intervalEnergy added to batterySupplied average powerCalculated time
20% to 50%24 kWh120 kW12 minutes
50% to 80%24 kWh60 kW24 minutes
Whole session48 kWh80 kW overall average36 minutes

The overall average is total energy divided by total time: 48 kWh ÷ 0.6 hours = 80 kW. It is not the simple average of 120 and 60, which would be 90 kW. The intervals add equal energy, but the slower interval lasts twice as long. The overall time-weighted average reflects that difference.

The 36-minute calculation is 12 minutes longer than the 24-minute constant-120-kW benchmark and 16.8 minutes longer than the constant-150-kW benchmark. It does not prove the actual vehicle will charge in 36 minutes. Replace the fictional interval averages with evidence relevant to the actual session, and still allow for uncertainty.

Change the target before changing the rate

For a separate branch, keep the same starting charge, usable-energy assumption and two supplied interval powers, but stop at 60%. From 20% to 50%, the result remains 24 kWh and 12 minutes. From 50% to 60% is ten percentage points, or 8 kWh; at the supplied 60 kW average for that subinterval, it takes 8 minutes.

The 20% to 60% branch therefore adds 32 kWh in 20 minutes. This calculation expressly assumes the second interval's 60 kW average also applies to the 50% to 60% portion. An average over the entire 50% to 80% interval would not, by itself, prove the same average for each part. If only the whole-interval average is known, the 20-minute result is a separate assumption, not a measured breakdown.

Do not infer that 60% is enough for a real trip from this arithmetic. The energy needed depends on the actual vehicle, route, weather, speed, terrain, charging options and desired reserve. Use the vehicle's applicable planning information and leave appropriate margin; never rely on the fictional 80 kWh mapping as a guarantee of distance.

For its Supercharger network, Tesla notes that charging slows as the battery fills and that reaching 100% typically takes substantially longer than reaching 80%. That manufacturer statement concerns its service and vehicles; it is not a universal rule that the final 20% always takes a fixed number of minutes.

Add the other parts of the stop

Suppose the fictional driver reaches the station at 7:00. The supplied planning scenario allows 12 minutes waiting, 2 minutes to connect and start and 36 minutes charging. Under those exact assumptions, the driver finishes at 7:50. A 50-minute station stop is longer than the 36 minutes of energy delivery.

If the vehicle must be ready to leave by 8:00, the supplied scenario has ten minutes of slack. That slack is not a reservation or a guarantee: a longer queue, an unavailable connector, a failed start or a slower session can use it. If the 12-minute wait is not known until arrival, label it as a scenario rather than calling the charger available.

In a separate delayed branch, waiting takes 25 minutes while connection and charging remain 2 and 36 minutes. The station stop becomes 63 minutes, and a 7:00 arrival ends at 8:03. This branch misses the stated 8:00 departure by three minutes. It does not establish that the driver should leave with less energy or attempt an unsafe drive.

Trip time may also include a detour to the station, a walk, a receipt or a different departure location. Include only what the decision needs and avoid counting the same minutes twice. The planning question is an actual schedule with an uncertain charging interval, not simply how long the charging cable is connected.

Check the equipment and measurement boundary

Identify the actual vehicle and charging connector, the station's access and compatibility information, and the applicable vehicle instructions. A displayed station power rating does not establish that the connector fits, the station is working, the car supports that power, or every stall can supply it at that moment. Confirm those questions through the relevant provider and vehicle information.

For AC charging, the vehicle's onboard equipment and the supply arrangement can affect delivered power. For DC fast charging, the station and vehicle still interact under their respective limits. This guide does not prescribe a connector, electrical installation, current setting or adapter. A qualified professional should assess any home electrical work and applicable local requirements.

The energy boundary is equally important. If a station reports energy delivered at its meter while the vehicle reports a change in stored battery energy, the two figures can differ. The worked 48 kWh is a battery-side assumption. It does not say the station meter must show exactly 48 kWh or that a quoted price per grid kWh applies to precisely that amount.

Likewise, battery capacity in kWh is not charging power in kW. A vehicle with an 80 kWh usable-energy assumption does not charge at 80 kW simply because the numbers match. One is an amount; the other is a rate. A power figure without a time interval cannot establish energy delivered.

What a session record can teach

After an actual session, record the vehicle, station, start and end times, starting and ending indicated charge, energy reported and the boundary of that energy measurement. Note any interruption or waiting separately. If available, retain the charging-power history or a reliable interval average rather than only the highest rate briefly displayed.

A simple average for a session can be calculated from the energy and elapsed charging time only if they refer to the same measurement boundary. For the fictional case, 48 kWh battery-side over 0.6 hours is 80 kW. Dividing a station-meter amount by a battery-side interval would instead produce a different quantity, not the same battery-side average.

One session is evidence about that session, not a guarantee for the next one. Temperature, starting charge, target, equipment, other loads or vehicle conditions can differ. A shorter or longer result may also reflect a different wait or setup period rather than a changed charging curve. Keep the timestamps and measurement definitions with the result.

If the vehicle or equipment reports a charging fault, follow its instructions and contact the appropriate provider or service team. Do not open electrical equipment or try to defeat a connector or safety system to achieve the fictional rate. The cause and safe response depend on the actual device and warning.

Do not turn charging time into cost or range

A 36-minute charging interval does not establish its price. Charging fees may be based on energy, time, session or other applicable terms. Identify the actual pricing basis, billing boundary, start and end conditions and any separate fees. A quoted per-kWh amount cannot be applied confidently to the battery-side 48 kWh unless the billable energy is known.

Nor does 48 kWh automatically provide a fixed number of miles. Vehicle energy use varies with conditions, and an energy calculation does not supply the vehicle's actual efficiency or trip reserve. A range estimate, battery health evaluation and charging-time model are related but answer different questions.

For home charging, the whole-house electricity tariff and any equipment or installation costs also matter. The separate home-charging-cost question requires the bill's actual measurement and tariff; this example does not evaluate whether switching tariffs or buying equipment will save money.

Leave a plan with assumptions attached

  1. State the vehicle, starting and target charge levels and the evidence for the energy difference.
  2. Identify the applicable charger, connector, access and vehicle limitations.
  3. Use battery-side interval-average power or another consistently measured basis; do not substitute the advertised peak.
  4. Break the session into supported intervals when power changes, then add their times.
  5. Keep queue, connection, detour and departure time separate from charging time.
  6. Record uncertainties and use actual vehicle guidance for trip energy and reserve.

In the fictional two-interval case, 48 kWh is added in 36 minutes: 12 minutes for the first 24 kWh and 24 for the second. A 12-minute wait and two-minute start make the station stop 50 minutes. Those numbers are useful because the inputs are visible; changing a vehicle, charge interval or average power requires a new calculation.

Explore Infinite Upside

For Vijay Sheth’s personal accounts, read Infinite Upside: Building Wealth With Room to Live, published by Sheth Capital, Inc.

Find your edition · Chapter companion

Explore more practical guides

The Reading Room

ABOUT THE CONTRIBUTOR

Luna Lim

DIRECTOR OF FINANCIAL RESEARCH & EDITORIAL STRATEGY

SHETH CAPITAL, INC.

Luna Lim writes about business, investing, and the judgment behind financial decisions. She joined PCH Exotics Inc. as Director of Operations in 2022, working across La Jolla and Miami. Today, she reports directly to Vijay Sheth at Sheth Capital, Inc., bringing an operator’s perspective to the ideas she covers.

Based in Pacific Beach, California, Luna is curious about the people behind the numbers: what they’re building, how they weigh uncertainty, and what makes a risk worth taking. Her articles for Infinite Upside follow those questions through the details, with clear explanations and a feel for how decisions play out in everyday business.

More from Luna Lim

The Infinite Upside store