A commercial tenant receives an electricity invoice for 4,000 kilowatt-hours. The landlord's building-wide bill is much larger. The lease mentions a submeter, a billing rate and a share of common-area costs. Before deciding whether the invoice makes sense, the tenant needs to know what the meter actually measures and how the numbers became a charge.
A submeter measures a portion of a building's use. It can help identify a tenant's electricity consumption, but it does not automatically explain shared equipment, demand charges, estimated readings, fees or the rules for allocating a master utility bill. The meter, the lease, the utility tariff and any applicable local requirements each answer different questions.
Start with the bill and the meter readings. Follow the calculation through the agreement. If a number cannot be traced, keep it open as a question rather than filling the gap with a convenient guess.
A submeter measures a portion, not necessarily the whole bill
The U.S. Department of Energy's federal metering guidance defines a submeter in its federal-building context as subordinate to a building's main meter, recording a portion of energy or water consumption. It may isolate a particular system or tenant. That is a useful technical description, not a statement that every commercial lease uses the same billing arrangement.
A tenant submeter might measure lighting and receptacles within the premises while central heating, cooling, elevators or common-area lights are supplied elsewhere. A different installation may include more or fewer circuits. Ask for a description or diagram of what the meter serves and whether any known shared load passes through it.
A DOE study of separate tenant spaces discusses examples where tenant meters measure lighting and plug loads while shared HVAC is handled separately. It is a study of practices, not a guarantee about your particular building. The actual electrical configuration and lease control the calculation.
Follow a reading from start to finish
Request the meter identifier, opening and closing readings, reading dates, units, any multiplier and whether the readings were actual or estimated. Ask who takes them and how a corrected reading appears on a later invoice. Confirm that the identifier on the invoice matches the tenant's meter.
In a fictional example, a meter reads 18,200 kWh at the beginning of the period and 22,200 kWh at the end. With an assumed multiplier of one and no rollover or correction, the indicated use is 4,000 kWh: 22,200 minus 18,200. That is consumption over the stated reading period, not peak demand.
If the agreement specifies an illustrative rate of $0.18 per kWh for that measured use, the simple energy calculation is $720: 4,000 × $0.18. This excludes shared costs, taxes, fixed charges and any other provision. It is an invented example, not a utility quote or a conclusion that a particular rate is lawful.
Compare the reading period with the utility billing period. If the tenant's meter is read on different dates, a direct comparison of one tenant invoice to one master bill may contain different days. Obtain the actual periods before interpreting the difference.
Where did the rate come from?
The lease may specify a utility rate, a formula based on the master bill, a fixed rate, a separate meter-service charge or another approach. Laws and utility rules can also affect what charges are permitted. Read the complete agreement and ask the appropriate utility, regulator or qualified adviser about the actual arrangement.
Ask whether the quoted rate covers only energy consumption or also includes some share of demand, fixed charges, taxes or other items. If the building calculates an average cost per kWh from the master bill, identify exactly which components and periods enter that average. An average can be a contractual allocation method without being the same as the marginal price for one extra kilowatt-hour.
Do not assume the highest rate on a utility bill applies to every tenant unit, or that dividing the entire bill by total kWh is the only valid method. The agreement and applicable rules matter. Request an itemized calculation and supporting records through the agreed process.
Shared loads need their own explanation
Central HVAC, hallway lighting and other common systems may not be recorded by a tenant's submeter. The agreement might allocate some costs by rentable area, operating expense provisions, measured use or another defined method. Check the denominator, included expenses, time period and whether the tenant's own metered use is already part of that allocation.
Suppose a fictional lease allocates $10,000 of an identified common electricity cost among 50,000 rentable square feet, and the tenant's defined share is 5,000 square feet. Under those stated assumptions, the tenant's 10% share is $1,000. That does not establish that every cost on an actual building bill belongs in the common pool.
Ask whether the $10,000 excludes charges already billed through tenant submeters. If the same energy is included in both the measured charge and the common pool, investigate how the agreement prevents double recovery. A name like “common electric” does not by itself identify the underlying meter or expense.
Demand and energy are different quantities
Kilowatt-hours measure energy over time. Demand charges generally concern a measured rate of use, commonly expressed in kilowatts, under a tariff's specified interval and other conditions. A submeter that records monthly kWh alone may not show the information needed to reproduce a demand allocation.
For example, two tenants could use the same number of kWh during a month but have very different operating schedules. Their individual peaks might occur at different times, and neither individual peak necessarily equals its contribution to the building's peak. Whether that distinction affects their bills depends on the metering, tariff and lease.
The related business demand-charge guide explains peak intervals and billing floors. For a submeter invoice, ask which demand quantity is allocated, the relevant time period, the source data and the agreement's formula. Do not multiply a tenant's kWh by a kW demand rate without a defined calculation that supports it.
What if the meter was estimated or changed?
A failed communications link, inaccessible meter, replacement device or delayed reading can create an estimate. Ask which dates were estimated, what method was used and when the estimate will be reconciled to actual readings. If the meter was replaced, record the final reading of the old device and initial reading of the new one, along with any multiplier or interval change.
For a meter replacement, assume an old meter’s final reading is 8,300 kWh after an opening reading of 8,100, and the new meter starts at 50 and ends at 350. With a multiplier of one for both and no overlap, gap or correction, the combined period is 500 kWh: 200 on the old meter plus 300 on the new one. The new meter’s 350 reading is not added to the old meter’s 8,300 total. Actual dates, multipliers and any overlap or missing period need their own verification.
In a fictional two-month example, a tenant was billed for an estimated 3,500 kWh in month one. A later actual reading shows 7,800 kWh used across both months. If the first estimate is retained in the ledger and there are no other adjustments, the remaining consumption to allocate to month two is 4,300 kWh: 7,800 minus 3,500. The applicable periods and rates still need to be checked.
That example does not say every estimate is valid or that the second month must use the same rate. It illustrates why a correction should identify the original estimate, actual total and prior amount billed. Rebilling the full 7,800 kWh without crediting the first 3,500 would count the same use twice under these assumptions.
Investigate an unexpected increase
Start with the simplest comparisons: reading dates, actual versus estimated status, multiplier, rate, prior credit and changes in operating hours or equipment. A longer reading period can increase total kWh even if average daily use is unchanged. Weather, occupancy, new equipment or a change in a shared system can also affect use, but do not assign a cause until the evidence supports it.
Ask whether the meter was inspected, replaced or recalibrated and whether the metered circuits still match the premises. The landlord or a qualified electrical professional can investigate the configuration safely. Tenants and office staff should not open electrical panels or disconnect equipment to test a billing theory.
If the lease provides a process for requesting supporting data or disputing a statement, follow its timing and delivery requirements. Applicable law may provide additional rights or duties. Keep payment obligations and the dispute process separate; do not assume a disputed invoice can be withheld without consequences.
Read the full lease, not only the utility clause
Definitions may appear in several places: premises, rentable area, operating expenses, exclusions, audit rights and billing procedures. Check amendments and any side letter. A tenant may pay measured electricity directly, reimburse a landlord, contribute to common expenses or have some combination of those arrangements.
Look for who pays for meter installation, reading, maintenance and replacement; which rates or administrative charges may be used; how common loads are handled; and how errors are corrected. Ask whether a right to review records exists and whether it has a deadline. A summary prepared during the tour may not reflect the signed agreement.
Regulation of submetering and resale varies by jurisdiction and arrangement. A charge that is permitted in one place or lease is not automatically permitted in another. For a significant dispute, obtain the actual tariff, agreement and qualified local advice before drawing a legal conclusion.
Compare periods on the same basis
A meaningful trend uses comparable dates, units, meter identifiers and rates. Convert consumption to average daily kWh when periods differ, while noting that operating days and weather can still vary. For example, 4,000 kWh over 20 days averages 200 kWh per day; 4,500 kWh over 30 days averages 150 kWh per day. The longer period has a larger total but lower simple daily average.
That average is a screening tool, not a diagnosis. A business with different weekend hours, seasonal cooling or a production shutdown may need a more detailed comparison. If interval data exist, ask whether they can help explain when consumption changed. Protect other tenants' information when requesting building records.
Questions to bring to the next invoice
Which meter and circuits are billed? What are the opening and closing readings, dates, units and multiplier? Are the readings actual or estimated? What agreement and tariff support the rate, and which charges are separate?
How are shared loads and demand allocated, and how is double counting avoided? Who corrects a meter error, and how will a credit or adjustment appear? A transparent calculation will not make electricity free, but it makes the conversation about the bill much more productive.