How Do You Size a Tankless Water Heater?

The impressive flow-rate number only makes sense alongside the water temperature.

A tankless water heater can look like the obvious answer to a very ordinary complaint: the last shower in the morning keeps turning cold. But the capacity number on the box is not a promise that every tap can run hot at once, in every season. The useful question is how much hot water the equipment can deliver at the temperature rise your building actually needs.

Tankless sizing combines the desired hot-water flow at the same time with the difference between incoming and outlet water temperatures. Colder incoming water generally means a larger temperature rise for the same target outlet, and a unit's available flow depends on its rated capacity under those conditions. The U.S. Department of Energy's tankless transition guide describes this relationship and the need to examine simultaneous uses.

First find the temperature rise

Temperature rise is the target outlet temperature minus the temperature entering the heater. Suppose a fictional building receives water at 50°F during a cold period and the heater is set to deliver 120°F. The simplified rise is 70°F: 120 minus 50. If the incoming water is 65°F, the same outlet target calls for a 55°F rise.

That difference changes the comparison even though the shower handle and the equipment model have not changed. Manufacturers provide performance information for particular models at different rises or inlet conditions. Read the actual table and its assumptions; do not take a maximum flow number observed at a modest rise and assume it applies when the supply is colder.

The 120°F figure is an example rather than a universal setting recommendation. Local requirements, equipment instructions, household needs and safety considerations matter. A higher setpoint can increase scald risk and changes the required rise; a lower setting can have other implications for a particular system. Ask a qualified installer about the complete system, controls and applicable requirements rather than adjusting a heater solely to make the capacity math look better.

Flow is about overlap, not the number of taps

The next input is the flow the heater must serve at one time. A house can have several bathrooms without every fixture running together. Conversely, a small household may routinely run a shower while a kitchen fixture or appliance is operating. A useful plan starts with realistic concurrent use, not just a count of rooms.

Imagine that the needed hot-water flow through a heater is estimated at 1.5 gallons per minute for one use and 1.0 gallon per minute for another, both at the same time. Under those fictional assumptions, the combined heater flow is 2.5 gallons per minute. The relevant product question is whether the selected model can provide that flow at the required temperature rise. Check the manufacturer's chart rather than comparing 2.5 with a single unexplained marketing number.

There is a subtle distinction between mixed water at a showerhead and hot water passing through the heater. A shower set below the heater outlet temperature mixes hot and cold water, so its total mixed flow is not automatically the same as its hot-water draw. The proportion depends on inlet, hot and mixed temperatures, along with the system's actual behavior. A dishwasher or other device may have its own operating pattern. An installer can use the actual fixtures and simultaneous-use assumptions to construct a defensible estimate.

Write the assumption next to each figure. If the estimate uses total mixed fixture flow as a conservative shortcut, say so. If it uses calculated hot-side flow, state the temperatures. Mixing the two approaches in one list can make the proposed capacity look more precise than it is.

What happens when the ground water gets colder?

Incoming water temperature changes by location and season, and a measured value on a warm afternoon may not represent the colder period that determines sizing. Ask the local water supplier, the installer or another reliable local source what temperature should be used for design. Record whether the figure is a measured minimum, an estimate or a published design value.

Then compare at least two operating points in the manufacturer's documentation: a typical condition and the colder condition. If the chart shows less allowable flow at the larger rise, consider whether the expected overlap fits at that point. If it does not, the choices may include a different unit, more than one properly designed unit, a change to the expected concurrent demand or another system configuration. Each has its own installation and operating implications.

There is no need to assume that a cold-water temperature, fixture flow or family schedule from a national example describes your own building. Ask the person making the proposal to show the numbers behind the selection. A short table with inlet temperature, outlet target, rise and simultaneous hot flow is often more revealing than an oversized model name in a quotation.

The equipment is only part of the project

Gas-fired and electric units have different supply and installation requirements. A gas proposal may depend on the available gas supply, combustion-air arrangement, venting and condensate provisions for the model. An electric proposal may depend on electrical service and circuit capacity. An existing installation may also need plumbing, controls or access changes. The Department of Energy's gas tankless overview describes equipment and installation considerations; the manufacturer's current instructions and locally applicable rules govern the actual project.

Request an itemized installed scope. Does the price include the equipment, required supply changes, venting or electrical work, permits where required, removal of the old heater, startup and any necessary finish work? What is excluded? Two bids can quote the same appliance and still represent materially different jobs.

Maintenance deserves its own line. Water conditions and equipment design can affect service needs. Ask the installer what the manufacturer recommends, who will perform it, where isolation and service access are located, and what those visits are expected to cost. Treat a contractor's estimate as an estimate and verify the actual service plan; no universal interval can be inferred from an advertisement.

On demand does not mean instant at the faucet

A tankless heater heats water as it passes through the unit, but hot water still has to travel through the distribution pipes to the fixture. Pipe length and configuration, the location of the heater and any recirculation design can affect the wait. The unit also has operating and activation characteristics specified by its manufacturer. Ask about the full plumbing path if the reason for replacing the heater is a long wait at a distant sink.

Similarly, “unlimited hot water” is too broad to make a buying decision. A correctly sized unit can continue heating while its operating conditions and supplies are maintained, but its output has a capacity limit at a given temperature rise. A power interruption can also matter to equipment that requires electricity, including some gas-fired systems. Ask which components need power and what the manufacturer says about operation during an outage.

Read the chart at the operating point

A manufacturer's table may present inlet temperature in one column and flow in another, or it may show temperature rise against gallons per minute. Check which temperature the chart uses before comparing models. A device rated at a given output under one set of conditions is not necessarily rated for the same output at a larger rise. The units and the test conditions belong beside the headline number in your notes.

For a fictional comparison, assume a product chart says a model supplies 3.0 gallons per minute at a 70°F rise and 4.0 at a 50°F rise. If the design condition is 70°F and the estimated concurrent heater flow is 3.5 gallons per minute, the 4.0 figure does not establish that this model meets the design case. This is an illustration, not a real equipment rating. Ask the installer to use the exact current documentation and check all applicable derating or installation conditions.

Compare the complete costs and benefits

Tankless equipment avoids storing a tank of hot water, but that feature alone does not establish the lifetime cost of a particular replacement. Compare installed cost, expected energy use under realistic demand, utility rates, maintenance and the useful life assumptions in both bids. A comparison with a heat-pump water heater or a modern storage unit may look different from a comparison with an aging inefficient appliance.

Do not turn a national efficiency figure into a promised bill reduction. The old heater's actual condition, the building's usage and local prices can change the result. Our guide to checking energy retrofit savings shows how to ask which assumptions drive an estimate.

Before choosing, ask for the cold incoming-water assumption, target outlet temperature, calculated rise, concurrent heater flow and the exact model's performance at that combination. Then review installation scope, operating requirements and maintenance. Those details turn a box with a large number on it into a system designed for the way the building is actually used.

Explore Infinite Upside

For Vijay Sheth’s personal accounts, read Infinite Upside: Building Wealth With Room to Live, published by Sheth Capital, Inc.

Find your edition · Chapter companion

ABOUT THE CONTRIBUTOR

Luna Lim

DIRECTOR OF FINANCIAL RESEARCH & EDITORIAL STRATEGY

SHETH CAPITAL, INC.

Luna Lim writes about business, investing, and the judgment behind financial decisions. She joined PCH Exotics Inc. as Director of Operations in 2022, working across La Jolla and Miami. Today, she reports directly to Vijay Sheth at Sheth Capital, Inc., bringing an operator’s perspective to the ideas she covers.

Based in Pacific Beach, California, Luna is curious about the people behind the numbers: what they’re building, how they weigh uncertainty, and what makes a risk worth taking. Her articles for Infinite Upside follow those questions through the details, with clear explanations and a feel for how decisions play out in everyday business.

More from Luna Lim

The Infinite Upside store