Comparing Ship and Shore-Power Emissions

Removing an onboard source and changing the wider emissions account are different results.

A ship plugs into shore power. Its auxiliary engines stop supplying the connected electrical load, but the emissions question is not finished. Some onboard sources may remain active, engines may run during connection and disconnection, and the electricity supplied from shore has its own generation boundary.

An adequate comparison preserves those parts separately. A local exhaust reduction, an electricity-related emissions estimate and a health benefit are different conclusions requiring different evidence.

The EPA’s December 2022 Shore Power Technology Assessment, section 5, identifies vessel load, operating hours, engine factors, electricity factors and grid losses as inputs. Its executive summary also states that shore power does not eliminate emissions from boilers and other sources that remain operational. The original calculation below uses specifically dated table entries, not current emissions factors or an actual port forecast.

Freeze the historical factor set

EPA’s 2022 report contains several dates. Table 10 supplies auxiliary-engine factors. Table 11 is labeled “2018 eGRID annual emissions rates,” even though surrounding discussion also describes a 2019 subregion map. The comparison here uses the table’s stated 2018 factor vintage.

Select the Table 10 row labeled Tier II, MGO with 0.10-percent sulfur. Its entries used here are 696 grams of carbon dioxide per kWh and 10.5 grams of nitrogen oxides per kWh. These are selected historical inventory factors, not proof of a particular vessel’s measured performance or current compliance classification.

Select the Table 11 WECC California entries: 225.22 grams of CO2 per generated kWh, 0.21 grams of NOx per generated kWh, and a grid gross loss fraction of 0.0480. The calculation preserves CO2 as CO2; it does not substitute the table’s separate CO2-equivalent column.

The report also discusses later calculator versions. Changing to a different calculator or electricity dataset requires its own version record. Calling the source “EPA data” is not enough to make coefficients from different vintages interchangeable.

Define a fictional call

Suppose a ship has a constant 1,000-kW electrical hotel load during a twelve-hour berth stay. Without shore power, its auxiliary engines supply that load for all twelve hours.

In the shore-power alternative, connection and disconnection together occupy two hours, during which the auxiliary engines supply the same load. Shore power supplies the other ten hours. The two-hour allowance is an invented case assumption, not the report’s default or a universal connection time.

Assume no additional terminal conversion losses in this teaching case beyond the specified grid gross loss adjustment. The 1,000-kW load is measured at the ship’s electrical input. Neither an auxiliary-engine nameplate nor a berth’s installed capacity is being substituted for actual load.

The no-shore alternative needs 12,000 kWh from auxiliary generation. The shore alternative needs 2,000 kWh from those engines and 10,000 kWh delivered through the shore connection. Both serve the same stipulated ship load over the same twelve hours.

That matched activity is essential. Comparing twelve hours of engine operation with only ten hours of total service would make some of the apparent emissions reduction a reduction in the service being supplied.

Account for generation before applying its factor

The selected eGRID factors are at generation. Delivering 10,000 kWh to the stipulated ship input requires more generation when grid losses are included.

Using the report’s Equation 1, required generation is 10,000 divided by one minus 0.0480, or approximately 10,504.20 kWh. The additional 504.20 kWh represents the loss allowance within this particular comparison boundary.

Multiplying the ship’s received energy directly by a generation factor would omit that allowance. Adding 4.8 percent to the delivered number is also not the same calculation: 10,000 × 1.048 is 10,480, rather than 10,504.20. The loss fraction is defined relative to generation in this equation.

A real comparison must identify whether additional transformers, conversion equipment or other shore-side loads are already included in the metered energy and factors. Applying a loss twice would be as misleading as omitting it. The teaching calculation intentionally isolates one supplied loss term.

Calculate CO2 without changing the pollutant

At 696 grams per kWh, the 12,000-kWh auxiliary-engine baseline produces an estimated 8,352 kg of CO2 in this factor-based exercise.

In the shore alternative, the engines’ remaining 2,000 kWh produce 1,392 kg. The 10,504.20 kWh of estimated electricity generation, multiplied by 225.22 grams per kWh, adds about 2,365.76 kg.

The combined figure is approximately 3,757.76 kg, giving a difference of about 4,594.24 kg against the baseline. These are calculated differences under the chosen historical factors and invented activity assumptions. They are not monitored emissions or a prediction for a 2026 project.

The local auxiliary-engine reduction is a different number: 8,352 minus 1,392 equals 6,960 kg. Electricity-generation emissions occur within the separate boundary represented by the grid factor. Subtracting them changes the broader CO2 account, not the amount removed from that ship’s auxiliary-engine exhaust at the berth.

CO2-equivalent would require the corresponding greenhouse-gas accounting choices and factors. It should not be created by relabeling the CO2 result. The selected report tables contain both types of column, which is why retaining the actual pollutant label matters.

Repeat the account for NOx

The auxiliary-engine baseline produces 12,000 × 10.5 grams, or 126 kg of NOx. Remaining engine operation in the shore alternative produces 21 kg.

The selected electricity factor adds about 2.206 kg of NOx, giving roughly 23.206 kg across the chosen engine-plus-generation boundary. The calculated difference from the baseline is about 102.794 kg.

At the berth, the avoided auxiliary-engine NOx is 105 kg. That is larger than the broader factor-based difference because the latter includes the estimated generation contribution. The two results are not competing estimates of the same location-specific event.

Nor can the kilograms alone establish an exposure or health outcome. That would require evidence about where pollutants are emitted, their dispersion, population exposure and the relevant health relationship. A port-wide inventory is not automatically a neighborhood-impact model.

The point is to keep each conclusion attached to its boundary. A statement about removing a shipboard source can be supported without pretending that the power system has no emissions. A broader emissions estimate can be calculated without pretending that emissions in different places create identical local exposure.

Preserve sources that did not change

Add a separate invented onboard source that emits 100 kg of CO2 per hour throughout the berth stay and is unaffected by the shore connection. It contributes 1,200 kg to each alternative.

The expanded baseline becomes 9,552 kg. The expanded shore alternative becomes approximately 4,957.76 kg. Their difference remains 4,594.24 kg because the unchanged source cancels in the comparison.

It still matters for a claim about total onboard emissions. The shore alternative has not become emission-free. A source can cancel from a difference while remaining physically present in both totals.

The added 100-kg/hour source is a teaching assumption, not a boiler factor from the EPA report. Actual boilers and other vessel systems require their own activity and emissions evidence. The report’s exception is a reason to investigate those sources, not permission to invent their values in a real inventory.

Connection time can change the result

If only eight of the twelve berth hours can use shore power, four hours remain on auxiliary engines. The same method must be repeated with 8,000 kWh delivered from shore and 4,000 kWh from the engines.

Under the fixed load and factors in this example, avoided engine operation and associated generation requirements both scale with connected hours. Eight connected hours therefore produce eight-tenths of the ten-hour case’s calculated CO2 difference, about 3,675.39 kg.

An actual ship’s load may change through the call, so hours alone may not scale the result. Connecting during a high-load part of the stay can displace a different quantity of engine generation than connecting during a low-load period. Matched load and connection records are stronger evidence than a blanket assumption that every berth hour is connected.

The same issue affects annual projections. A berth with installed equipment is not proof that every visiting ship can connect, that every eligible call does connect, or that all connected hours carry the same load. The annual activity record needs those distinctions before it becomes an annual emissions estimate.

Keep the comparison separate from other electricity claims

The CO2 comparison also has a break-even generation factor within these assumptions. For each kWh supplied to the ship, the engine alternative uses a 696-gram factor. The shore alternative requires 1 divided by 0.952 generated kWh. Its generation factor must therefore be below 696 × 0.952, or 662.592 grams per kWh, for the substituted electrical service to have the lower CO2 estimate in this limited account.

That threshold is calculated from the fictional matched activity and selected factor convention. It is not a regulatory standard or a recommended electricity mix. The selected historical factor of 225.22 is below it.

For a separate sensitivity, invent a generation factor of 800 grams of CO2 per kWh while retaining the same loss fraction and activity. Grid generation would then contribute approximately 8,403.36 kg. Adding the remaining engine contribution gives 9,795.36 kg, about 1,443.36 kg more than the 8,352-kg engine-only baseline.

The ship’s local auxiliary-engine CO2 reduction would still be 6,960 kg. Changing the wider generation factor does not change the stipulated local engine hours. This counterexample shows why a local-source reduction cannot, by itself, prove the sign of a broader CO2 comparison.

The invented 800-gram factor is not assigned to any actual region or year. It is a sensitivity input used to reveal the boundary, not a substitute for obtaining the appropriate factor for an actual assessment. Other pollutants would need their own factors and calculations rather than inherit the CO2 conclusion.

The Scope 2 reconciliation guide concerns organizational accounting methods and eligible evidence for purchased electricity. This article instead follows a defined physical activity comparison using a named historical average generation factor. A contractual electricity claim does not silently replace that coefficient in this calculation.

Likewise, an average eGRID factor does not directly establish the marginal emissions caused or avoided by a particular future connection. Such a causal question needs an appropriate electricity-system analysis. The historical-factor exercise should not acquire that stronger label after the arithmetic is finished.

A useful port comparison preserves the ship load and call record, connected and unconnected periods, factor versions, losses, pollutant labels and unchanged sources. It then reports the local and broader results separately. That leaves a reader able to reconstruct the conclusion—and identify exactly which evidence would have to change before using it for a different year or project.

Explore Infinite Upside

For Vijay Sheth’s personal accounts, read Infinite Upside: Building Wealth With Room to Live, published by Sheth Capital, Inc.

Find your edition · Chapter companion

ABOUT THE CONTRIBUTOR

Luna Lim

DIRECTOR OF FINANCIAL RESEARCH & EDITORIAL STRATEGY

SHETH CAPITAL, INC.

Luna Lim writes about business, investing, and the judgment behind financial decisions. She joined PCH Exotics Inc. as Director of Operations in 2022, working across La Jolla and Miami. Today, she reports directly to Vijay Sheth at Sheth Capital, Inc., bringing an operator’s perspective to the ideas she covers.

Based in Pacific Beach, California, Luna is curious about the people behind the numbers: what they’re building, how they weigh uncertainty, and what makes a risk worth taking. Her articles for Infinite Upside follow those questions through the details, with clear explanations and a feel for how decisions play out in everyday business.

More from Luna Lim

The Infinite Upside store