Two Scope 2 numbers can describe the same purchased electricity without being two separate quantities to add together. A location-based estimate uses factors representing electricity generation in the relevant geographic area. A market-based estimate reflects eligible contractual instruments and other applicable factors under the chosen reporting framework. They are alternative views of the same activity, with different evidence requirements.
In this fictional illustration, an organization purchases 100,000 kilowatt-hours of grid electricity for one meter and reporting period. A stipulated location-based factor gives 40 metric tonnes of carbon dioxide equivalent (CO₂e). A separately stipulated market-based calculation gives 30 metric tonnes. The answer is not 70 tonnes: both totals cover the same 100,000 kWh. Their difference also does not, on its own, measure a physical reduction in emissions.
Define the activity before choosing factors
The case has one organizational boundary, one meter and one reporting period. It includes no exported or self-generated electricity, purchased steam or heat. Those omissions make the comparison easier to follow; an actual inventory may need additional activity and accounting treatment. Both methods below use the same 100,000 kWh for the same boundary and period.
For a real inventory, establish the organizational and operational boundaries under the applicable reporting framework. Gather meter readings or bills for the entire period, identify the facilities included and reconcile the total to the activity schedule. Check whether bills cover exactly the reporting dates or require supported estimates. Keep consumption records separate from demand charges, currency amounts and capacity figures: a kW peak is not a kWh total.
EPA’s Scope 1 and Scope 2 inventory guidance describes purchased-energy inventory reporting. Its emission factors hub provides factor resources that depend on geography and vintage. The factors in this guide are invented for the calculation and are not EPA factors. Actual reporting requires the relevant framework, version, geography, period, units and source documentation.
Calculate the location-based estimate
Assume the applicable fictional location factor is 0.4 kilograms CO₂e per kWh. Multiply 100,000 kWh by 0.4 kg CO₂e/kWh to get 40,000 kg CO₂e. Divide by 1,000 kilograms per metric tonne to obtain 40 metric tonnes CO₂e. The kWh units cancel; the remaining unit is mass of CO₂e.
| Location-based input | Fictional value |
|---|---|
| Purchased electricity | 100,000 kWh |
| Location factor | 0.4 kg CO₂e/kWh |
| Calculated emissions | 40,000 kg CO₂e = 40 metric tonnes CO₂e |
Keep the factor’s unit with the number. A factor expressed per megawatt-hour cannot be multiplied by kWh without converting units; one MWh equals 1,000 kWh. Likewise, do not label kilograms as tonnes. Factor selection and conversion deserve independent checks because a unit error can dominate the result even when the multiplication is correct.
Calculate the market-based estimate separately
For the same 100,000 kWh, stipulate that 50,000 kWh are matched to qualifying retired certificates with a market factor of 0 kg CO₂e/kWh. The remaining 50,000 kWh use a stipulated applicable residual market factor of 0.6 kg CO₂e/kWh. In the first portion, 50,000 × 0 = 0 kg CO₂e. In the second, 50,000 × 0.6 = 30,000 kg CO₂e. The sum within this method is 30,000 kg, or 30 metric tonnes CO₂e.
| Market-based portion | Activity | Fictional factor | Result |
|---|---|---|---|
| Matched qualifying instruments | 50,000 kWh | 0 kg CO₂e/kWh | 0 kg CO₂e |
| Remaining activity | 50,000 kWh | 0.6 kg CO₂e/kWh | 30,000 kg CO₂e |
| Total for this method | 100,000 kWh | Two separate factors | 30 metric tonnes CO₂e |
The two market-based portions add to the same 100,000 kWh used for the location-based method. That activity reconciliation is essential: it helps prevent applying a certificate to more electricity than is covered or leaving activity out of the calculation. The factors and the certificates’ qualification are stipulated here. The exercise does not certify any real instrument or claim that any real certificate has a zero factor.
Display the two results with their method labels, reporting period and organizational boundary: location-based 40 tonnes; market-based 30 tonnes. Do not add these alternative method totals. The 10-tonne arithmetic difference reflects the different accounting factors in this example; it is not a measurement of avoided generation, additionality or a change in physical grid emissions.
Check the instruments, not just the retirement record
Retirement alone does not prove an instrument is eligible for a particular market-based claim. For an actual report, examine the full quality criteria under the applicable framework and version. The evidence may need to establish the relevant attributes, exclusive claim, generation and consumption periods, market or geographic eligibility, instrument volume and appropriate retirement or cancellation. These examples are not a complete substitute for the framework’s criteria.
Build a record that links each instrument to the organization, reporting period, covered activity and supporting registry or supplier documentation. Check that the same attributes are not claimed twice across facilities or reports. If a supplier provides an emission factor, retain the source, period, unit and supporting information needed to assess whether it meets the applicable hierarchy and quality requirements. A contract label or invoice description alone does not settle those questions.
The example deliberately assumes the 50,000 kWh match qualifies. If an actual retirement record is missing or the attributes and geography cannot be verified, do not silently assign the fictional zero factor. Check the evidence and applicable factor hierarchy before selecting a reporting factor.
Distinguish a missing factor from a zero factor
For the remaining 50,000 kWh, the example stipulates an applicable residual factor of 0.6 kg CO₂e/kWh. A missing residual mix is not the same thing as a zero factor. Consult the hierarchy and disclosures applicable to the actual framework and reporting period. EPA’s purchased-electricity guidance describes a residual-mix preference and regional or national grid-average fallbacks where necessary, together with disclosure when a residual mix is unavailable. Do not assume that this specific guidance is the only rule for every reporting program.
If a permitted fallback is used, record its source, vintage, geography, units, reason for use and required disclosure. The report should distinguish a verified contractual factor from a fallback factor.
Do not simply apply the location-based factor to all unmatched market-based activity without checking whether the relevant hierarchy permits that choice and what must be disclosed. Conversely, do not claim that a residual factor is universally mandatory. The right answer depends on the framework and evidence available for the actual inventory.
See what changes when coverage changes
Keep the fictional 100,000 kWh, location factor of 0.4 kg CO₂e/kWh and residual factor of 0.6 kg CO₂e/kWh. In a separate scenario, suppose only 25,000 kWh are supported by qualifying zero-factor instruments, while the other 75,000 kWh use the stipulated residual factor. The market-based total becomes 25,000 × 0 + 75,000 × 0.6 = 45,000 kg CO₂e, or 45 tonnes. The location-based total remains 40 tonnes because its activity and factor were held fixed.
The market-based number can therefore be higher or lower than the location-based number in a fictional comparison. This variation does not establish which factor is appropriate in a real market or which certificate qualifies. It illustrates a control: the matched and remaining activity must still sum to 100,000 kWh, and the factors must apply to their own portions.
Suppose instead that the supporting instruments are for 60,000 kWh but the relevant facility consumed only 50,000 kWh in the eligible period. The extra 10,000 kWh cannot simply be assigned to that facility as though its eligible consumption were larger. Investigate whether and how the applicable rules allow the remaining attributes to be used elsewhere, and whether another claim has already been made. Do not infer eligibility from the face amount alone.
Resolve an incomplete meter period
Imagine that bills substantiate 90,000 kWh and the last month is missing, while the draft worksheet assumes a further 10,000 kWh. Until the estimate is supported, label the full 100,000 kWh as provisional. Obtain the missing bill or meter data, or document an estimation method permitted by the applicable reporting framework and the uncertainty it introduces. Do not present the assumed 10,000 as a measured reading.
If the verified total later becomes 96,000 kWh, redo both methods on that same activity boundary. For a purely illustrative sensitivity, retain the stipulated 50,000 kWh eligible match, the 0.4 location factor and the 0.6 residual factor, assuming all remain applicable to the revised period. Location-based emissions would be 96,000 × 0.4 = 38,400 kg, or 38.4 tonnes. Market-based emissions would be 50,000 × 0 + 46,000 × 0.6 = 27,600 kg, or 27.6 tonnes.
Those revised totals are not proof that a real certificate or factor remains eligible after a period changes. Recheck the period, volume and evidence before applying them. The point is to update the activity base and the unmatched portion together, rather than changing only one method or retaining 50,000 kWh of residual activity from the earlier 100,000 kWh example.
Reconcile two facilities before rolling up
As a separate fictional data-control example, split the same 100,000 kWh into facility A at 60,000 kWh and facility B at 40,000 kWh. Assume both fall within the same reporting boundary and period and, solely for this exercise, the same stipulated 0.4 kg CO₂e/kWh location factor applies to both. Their location-based results are 24,000 kg and 16,000 kg respectively, totaling 40,000 kg. Real facilities may require different geographic factors; do not impose one factor merely to reproduce this total.
Now assume the same fictional 50,000 kWh of qualifying instruments are allocated once: 30,000 to A and 20,000 to B. Each facility has another 30,000 and 20,000 kWh respectively using the stipulated 0.6 kg CO₂e/kWh residual factor. A’s market-based result is 18,000 kg; B’s is 12,000 kg; together they total 30,000 kg. These assignments are assumed eligible, including geography and period. They do not demonstrate that any actual instrument can be split or allocated in this way.
A reviewer can trace four equalities: facility consumption totals 100,000 kWh; allocated instrument volume totals 50,000 kWh; unmatched activity totals 50,000 kWh; and each facility’s matched plus unmatched activity equals its consumption. These tests identify allocation errors even when the overall emissions total appears plausible. For example, assigning the same 30,000 kWh certificate block to both facilities would overstate coverage despite using an internally consistent factor.
Where facilities have different factors or instruments, retain separate rows and support each assignment before aggregation. Do not average factors first unless the averaging method and activity weights are appropriate and traceable. The two resulting organizational totals remain alternative method totals; facility rollup does not turn them into quantities to add together.
Make the review trail usable
Keep a compact inventory workbook with four linked records: the boundary and activity schedule; the location factors and source versions; the market instruments and eligibility evidence; and the residual or permitted fallback factors with disclosures. Each line should identify the period, geographic scope, units, calculation and evidence owner. Reconcile the kWh totals across the two methods and resolve missing or overlapping activity explicitly.
Have a reviewer check that each certificate or supplier claim is supported and not double counted, each factor uses the correct units, and kilograms are converted to metric tonnes correctly. Review the two totals as alternatives, then check the report’s labels and any required disclosures. If a factor, instrument or meter period remains unresolved, record the specific missing evidence and the applicable reporting decision instead of filling the gap with a convenient zero.
For the stipulated original inputs, the location-based result is 40 tonnes and the market-based result is 30 tonnes. Those calculations make sense only with the stated boundary, period and evidence assumptions. A reliable real-world inventory starts with substantiating those inputs and applying the framework that actually governs the report.
Explore Infinite Upside
For Vijay Sheth’s personal accounts, read Infinite Upside: Building Wealth With Room to Live, published by Sheth Capital, Inc.
Find an edition of Infinite Upside
Choose an edition